Electrical installation – Lenze 9300 0.37kW-75kW User Manual

Page 208

Advertising
background image

Electrical installation

Wiring of digital frequency input / digital frequency output

5

l

208

EDKVS9332X DE/EN/FR 6.1

5.11

Wiring of digital frequency input / digital frequency output

Installation material required from the scope of supply:

Description

Use

Quantity

Protective cover

Protection for unused Sub−D connections

4

Technical data

Field

Digital frequency output X10

Connection at drive controller

Connector: Socket, 9−pole, Sub−D

Pin assignment

Dependent on the selected basic configuration

Output frequency

0 ... 500 kHz

Signal

Two−track with inverse 5 V signals (RS422) and zero track

Load capacity

Max. 20 mA per channel
(up to 3 slave drives can be connected)

Special features

The "Enable" output signal at X10/8 switches to LOW if the drive
controller is not ready for operation (e.g. disconnected from mains). This
can trip SD3 monitoring on the slave drive.

Internal voltage source
(X10/4, X10/5)

DC 5 V / max. 50 mA
Total current at X9/4, X9/5 and X10/4, X10/5: max. 200 mA

Field

Digital frequency input X9

Connection at drive controller

Connector: Pin, 9−pole, Sub−D

Input frequency

0 ... 500 kHz (TTL level)

Signal

Two−track with inverse 5 V signals (RS422) and zero track

Signal evaluation

Via code C0427

Current consumption

Max. 5 mA

Special features

With activated SD3 monitoring, TRIP or warning is tripped if the "Lamp
Control" input signal at X9/8 switches to LOW.
Due to this the drive controller can respond if the master drive is not ready
for operation.

Wiring

)

Note!

ƒ

We recommend to use Lenze system cables for wiring.

ƒ

For self−made cables only use cables with shielded cores twisted in pairs.

Advertising