Electrical installation

Wiring of the feedback system

Resolver at X7

5

l

205

EDKVS9332X DE/EN/FR 6.1

5.10.2

Resolver at X7

Technical data

Field

Values

Connection at drive controller

Connector: Socket, 9−pole, Sub−D

Resolver type recommended

Receiver

Number of pole pairs of the resolver 1

Transmission ratio

0.3

Evaluation method

Voltage impression in the sine and cosine winding

Max. output voltage

± 10 V

Max. current consumption

50 mA per winding

Max. impedance [Z]

500

W per winding

Output frequency

4 kHz

Monitoring

Monitoring for open circuit of the resolver and the resolver cable
(configurable)

Wiring

+REF

-REF

+COS

+SIN

-SIN

-COS

+KTY

-KTY

1

2

3

4

5

6

7

8

9

X7

< 50 m

KTY

9300STD331

Fig. 5−32

Resolver connection

Cores twisted in pairs

X7 − Resolver
Connector: Socket, 9−pole, Sub−D

Pin

1

2

3

4

5

6

7

8

9

Signal

+REF

−REF

GND

+COS

−COS

+SIN

−SIN

+KTY

−KTY

0.5 mm

2

(AWG 20)

˘

0.14 mm

2

(AWG 26)