Mechanical installation, Mounting cutout in control cabinet – Lenze 9300 0.37kW-75kW User Manual

Page 142

Advertising
background image

Mechanical installation

Standard devices in the power range 15 ... 30 kW
Thermally separated mounting (push−through technique)

4

l

142

EDKVS9332X DE/EN/FR 6.1

4.2.3

Thermally separated mounting (push−through technique)

For mounting in push−through technique, the drive controller of type EVS93xx−Exx must
be used. In addition, the mounting set EJ0011 for the push−through technique is required.

Dimensions

h

c1

c2

c3

h

d1

d2

d3

d2

d

b

a1

a

g

b1

e1

e

L

9300std066

Fig. 4−5

Dimensions for thermally separated mounting 15 ... 30 kW

9300

Dimensions [mm]

Type

a

a1

b

b1

c1

c2

c3

d

d1

d2

d3

e

1)

e1

g

h

EVS9327−Ex
EVS9328−Ex
EVS9329−Ex

279.5

250

379.5

350

19

131

243

361.5

32

100

97

250

159.5

6

9

1)

For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Mounting cutout in control cabinet

9300

Dimensions [mm]

Type

Width

Height

EVS9327−Ex
EVS9328−Ex
EVS9329−Ex

236

336