Standard devices with a power of 45 kw, Important notes, Mains connection, dc supply – Lenze 9300 0.37kW-75kW User Manual

Page 176: Electrical installation

Advertising
background image

Electrical installation

Standard devices with a power of 45 kW
Important notes

5

l

176

EDKVS9332X DE/EN/FR 6.1

5.6

Standard devices with a power of 45 kW

5.6.1

Important notes

To gain access to the power connections, remove the cover:

Remove the cover of the drive controller

0

1

1. Remove the screws

0

2. Lift cover

1 up and detach it

9300vec113

Installation material required from the scope of supply:

Description

Use

Quantity

Cable ties 3.5 × 150 mm

Strain relief/shield connection for motor cable

4

5.6.2

Mains connection, DC supply

)

Note!

ƒ

If a mains filter or RFI filter is used and the cable length between mains/RFI
filter and drive controller exceeds 300 mm, install a shielded cable.

ƒ

For DC−bus operation or DC supply, we recommend using shielded DC
cables.