Commissioning, Code table – Lenze EDK71MMXXX−010 User Manual

Page 110

Advertising
background image

7

Commissioning

Code table

EDK71MMXXX−010 DE/EN/FR 5.0

L

110

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0003

v

Save parameter
non−volatile

1

0

Do not save parameter in EEPROM

Data loss after mains
disconnection

1

Always save parameter in EEPROM

l

Active after every mains
connection

l

Cyclical changing of
parameters via bus
module is not allowed

3

Save separate basic setting in
EEPROM

Subsequently save with
parameter set 1 with
C0002 = 9 as separate
basic setting

C0004

Bar graph
display

54

1

{code no.}

989

l

Bar graph display shows
the selected value in %
after mains connection

l

Range
−180 % ... +180 %

54 = apparent current of motor 1 (C0054)

C0005

v

Fixed
configuration of
input signals

0

Code is individually
adjustable in four
parameter sets

0

All digital input signals are supplied
from terminal strip X3

Sets C0410/x = Lenze
setting

200

All digital input signals are fed from
fieldbus function module to FIF
(e.g. INTERBUS or PROFIBUS−DP)

Sets C0410/x = 200

255

All digital input signals are fed from
fieldbus function module to FIF
(e.g. INTERBUS or PROFIBUS−DP)

C0410/x was freely
configured

C0006

v

uSEr

Transfer
HW/*hand
terminal

0

C0012

C0016

C0120

l

Parameter setting of
codes via:
– PU: Potentiometer

"U

0

" for starting

voltage

– PT: Potentiometer "T"

for acceleration time

– S: Stepping switch for

rated motor current

– H: Hand terminal

l

With the parameter
setting via
potentiometer/switch,
you can check the
setting via hand terminal

l

When switching to hand
terminal, the values set
with PU, PT and S are
transferred.

0

PT

PU

S

1

PT

PU

H

2

PT

H

S

3

PT

H

H

4

H

PU

S

5

H

PU

H

6

H

H

S

7

H

H

H