Commissioning, Code table – Lenze EDK71MMXXX−010 User Manual

Page 116

Advertising
background image

7

Commissioning

Code table

EDK71MMXXX−010 DE/EN/FR 5.0

L

116

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0150

starttec status
word 1
(parameter
channel)

Query of status via parameter channel. The
most important status information is
summarised as bit pattern

l

Some bits can be freely
linked with internal
digital signals in C0417

l

On hand terminal:
Display only
(hexadecimal)

Bit

Assignment

0

Mapping of C0417/1

1

Mapping of C0417/2

2

Mapping of C0417/3

3

Mapping of C0417/4

4

Mapping of C0417/5

5

Mapping of C0417/6

6

Mapping of C0417/7

7

starttec released/inhibited

0 starttec released

1 starttec inhibited

11|10|9|8 Device status

0011 Operation inhibited

0110 Operation released

1000 Active fault

12

Overtemperature" warning

0 No warning

1 Housing temperature > +75 °C

13

Mapping of C0417/14

14

Mapping of C0417/15

15

Mapping of C0417/16

C0151

starttec status
word 2
(parameter
channel)

Bit

Assignment

l

The bits can be freely
linked with internal
digital signals in C0418

l

On hand terminal:
Display only
(hexadecimal)

0

Mapping of C0418/1

...

...

15

Mapping of C0418/16

C0156

Current
threshold

0

{1 %}

150 Programmable current

threshold
Reference: starttec rated
current 9.5 A

1 Motor 1

0

Configure signal output in
C0415

2 Motor 2

0