Troubleshooting, Error messages – Lenze EDK71MMXXX−010 User Manual

Page 130

Advertising
background image

Troubleshooting

Error messages

?

EDK71MMXXX−010 DE/EN/FR 5.0

130

L

Display

Remedy

Cause

Fault

Keypad

PC

1)

OH3

A

53

Motor temperature
too high (PTC or
thermal contact
responded)
(is generated only if
C0119 = 1)

l

Motor too warm from
excessive currents or
frequent and extended
acceleration operations

l

Check drive dimensioning

OH51

e

203

l

No PTC or thermal contact
connected at X3/T1 and
X3/T2

l

Connect PTC or thermal contact
or switch off monitoring

Pr1

A

72

PAR1 incorrectly
transmitted

PAR1 is defective

Data transfer must be repeated or
Lenze setting must be loaded before
release

Pr5

A

79

Internal fault

Consultation with Lenze is required

Pt5

A

81

Time fault with
parameter set
transfer

Data flow from hand terminal or
PC is interrupted, e.g. hand
terminal was removed during
the data transmission

Data transfer must be repeated or
the Lenze setting must be loaded
before release

rSt

A

76

Error with
Auto−TRIP reset

More than 8 error messages in
10 minutes

Dependent upon the error message

1)

LECOM fault number

Advertising