Electrical installation
Important notes
5
EDK71MMXXX−010 DE/EN/FR 5.0
85
L
Fuses and cable cross−sections
l
Dimension cable cross−sections according to the max. input current.
l
Observe national and regional regulations (e.g. VDE 0113, EN 60204)!
Installation to EN 60204−1
БББББ
БББББ
БББББ
FI
1)
Fusible cutout
Circuit breaker
X1/L1, L2, L3,
1U, 1V, 1W, PE
[mm
2
]
M25 A
B25 A
Max. 4
³30 mA
ББ
ББ
ББ
1)
БББББББББББББББББББ
БББББББББББББББББББ
БББББББББББББББББББ
Universal current−sensitive earth−leakage circuit breaker
l
Install earth−leakage circuit breaker only between feeding mains and starttec.
l
The earth−leakage circuit breaker can trip incorrectly by simultaneously switching in several starttec to
the mains.