Commissioning, Code table – Lenze EDK71MMXXX−010 User Manual

Page 125

Advertising
background image

Commissioning

Code table

7

EDK71MMXXX−010 DE/EN/FR 5.0

125

L

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0415

v

uSEr

(Cont.)

20

Apparent current (C0054) < current
threshold (C0156/1)

V−belt monitoring of
motor 1

21

Apparent current (C0055) < current
threshold (C0156/2)

V−belt monitoring of
motor 2

22

Reserved

24

Reserved

25

TRIP fault message

26 ...
31

Reserved

32

Digital input X3/E1

33

Digital input X3/E2

34

Digital input X3/E3

35

Digital input X3/E4

36

Digital input X3/E5

37

AS−I control bit D0

Only active for variant
E71MM402FxAxxx

38

AS−I control bit D1

39

AS−I control bit D2

40 ...
55

Reserved

60 ...
75

CAN−IN1.W1/FIF−IN.W1
Bit 0 (60) ... bit 15 (75)

80 ...
95

CAN−IN1.W2/FIF−IN.W2
Bit 0 (80) ... bit 15 (95)

100 ...
115

CAN−IN2.W1
Bit 0 (100) ... bit 15 (115)

120 ...
135

CAN−IN2.W2
Bit 0 (120) ... bit 15 (135)

255

Not assigned

C0416

v

Level inversion
of digital
outputs
A1 ... A4

0

X3/A4

X3/A3

X3/A2

X3/A1

The binary value of the
selection digit controls the
level pattern of the outputs:

l

0: Output is not inverted
(HIGH active)

l

1: Output is inverted
(LOW active)

0

0

0

0

0

1

0

0

0

1

2

0

0

1

0

3

0

0

1

1

4

0

1

0

0

...

15

1

1

1

1

Advertising