Commissioning, Code table – Lenze EDK71MMXXX−010 User Manual
Page 115
![background image](/manuals/566147/115/background.png)
Commissioning
Code table
7
EDK71MMXXX−010 DE/EN/FR 5.0
115
L
Code
Setting options
IMPORTANT
No.
Designation
Lenze Selection
C0135
starttec control
word
(parameter
channel)
Control of starttec via parameter channel.
The most important control commands are
summarised in bit commands
C0135 cannot be changed
by using the hand terminal
Bit
Assignment
0
Motor 1 start/stop
0 Stop motor 1
1 Start motor 1
1
Select motor 2 start/stop or
direction of rotation
0 Stop motor 2 or CCW rotation
1 Start motor 2 or CW rotation
2
Brake control
0 Release brake
1 Apply brake
3
Reserved
...
8
9
Release/inhibit starttec
0 Release starttec
1 Inhibit starttec
10
Trip set
Sets "External error" fault
(
EEr
, LECOM no. 91)
0 External fault active
1 No fault
11
TRIP reset
Cause of malfunction must
be removed
1
Þ 0 Edge resets fault
12
Reserved
...
15