7
EDK71MMXXX−010 DE/EN/FR 5.0
121
L
Code
IMPORTANT
Setting options
No.
Selection
Lenze
Designation
C0408 Minimum
operating time
0.00
{0.01 s}
20.00
l
Code is individually
adjustable in four
parameter sets.
l
The digital signal linked
with X3/Ex is active for
at least the time set
after a LOW/HIGH edge
at X3/Ex.
l
Each LOW/HIGH edge
during a running cycle
resets the time.
1 E1
0.00
start043
S (Ex)
S (Ex)
S (Ex)
Ex
Ex
Ex
t
C0408
C0408
2 E2
0.00
Ex:
Level at X3/E1 or X3/E2
S (Ex):
Digital signal linked with
X3/E1 or X3/E2
C0409 Logical
operation of
digital input
signals
Code is individually
adjustable in four
parameter sets.
1 E1
0
0
Not linked
1
E1 AND E4
2
E1 OR E4
2 E2
0
0
Not linked
1
E2 AND E5
2
E2 OR E5
3 E4
0
0
Not linked
1
E4 AND E5
2
E4 OR E5
4 E5
0
0
Not linked
1
E5 AND E4
2
E5 OR E4
Advertising