Commissioning, Code table – Lenze EDK71MMXXX−010 User Manual

Page 117

Advertising
background image

Commissioning

Code table

7

EDK71MMXXX−010 DE/EN/FR 5.0

117

L

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0161

Current error

Display of history buffer
contents
Hand terminal: three−digit
alphanumeric fault
identification

C0162

Last fault

C0163

Next to last
fault

C0164

Third to last
fault

C0165

Service code
LECOM

Changes only through
Lenze Service!

C0170

v

TRIP reset
configuration

0

0

TRIP reset by switching the 24 VDC
supply voltage, LOW edge at X3/28,
bus function module or

s

key

l

TRIP reset via bus
function module with
C0043, C0410/12 or
C0135 bit 11

l

Auto−TRIP reset
automatically resets all
faults after the time in
C0171 expires

1

Same as 0 and additionally
Auto−TRIP reset

2

TRIP reset by switching the 24 VDC
supply voltage or via bus function
module

3

TRIP reset by switching the 24 VDC
supply voltage

C0171

Delay for
Auto−TRIP reset

0.00

0.00

{0.01 s}

60.00

C0178

Operating hours

{h}

Display only
Total time terminal
X3/28 = HIGH

C0179

Mains
connection time

{h}

Display only
Total time of mains On

C0200

Software MPC

82S8213V_xyz00

Display at PC only
x = main version
y = subversion

z = 1

1 motor, brake = 180 VDC

l

TRIP reset via bus
function module with
C0043, C0410/12 or
C0135 bit 11

l

Auto−TRIP reset
automatically resets all
faults after the time in
C0171 expires

z = 2

1 motor, brake = 205 VDC

z = 3

1 motor, brake = 180 VDC, ASI

z = 4

1 motor, brake = 205 VDC, ASI

z = 5

2 motors, brake = 180 VDC

z = 6

2 motors, brake = 205 VDC

z = 7

2 motors, brake = 180 VDC, ASI

z = 8

2 motors, brake = 205 VDC, ASI