Commissioning, Code table – Lenze EDK71MMXXX−010 User Manual
Page 119
Commissioning
Code table
7
EDK71MMXXX−010 DE/EN/FR 5.0
119
L
Code
IMPORTANT
Setting options
No.
Selection
Lenze
Designation
C0354
v
Selective
system bus
address
0
{1}
513 Single addressing of
system bus process data
objects
1 CAN−IN1 (sync)
129
Effective for sync control
(C0360 = 1)
2 CAN−OUT1
(Sync)
1
3 CAN−IN2
257
4 CAN−OUT2
258
5 CAN−IN1 (time)
385
Effective for event or time
control (C0360 = 0)
6 CAN−OUT1
(time)
386
C0355
v
System bus
identifier
0
{1}
2047 Display only
1 CAN−IN1
Identifier of CAN1 for sync
control (C0360 = 1)
2 CAN−OUT1
3 CAN−IN2
4 CAN−OUT2
5 CAN−IN1
Identifier of CAN1 for event
or time control (C0360 = 0)
6 CAN−OUT1
C0356
v
System bus
time settings
1 Boot up
3000
0
{1 ms}
65000 Required for CAN
interconnection without
master
2 Cycle time
CAN−OUT2
0
0 and C0360 = 0:
event−controlled process
data transfer
> 0 and C0360 = 1:
cyclical process data
transfer
3 Cycle time
CAN−OUT1
0
0 = event−controlled
process data transfer
> 0 = cyclical process data
transfer
4 CAN delay
20
Delay time until beginning
of cyclical transmission
after boot−up