7

Commissioning

Code table

EDK71MMXXX−010 DE/EN/FR 5.0

L

122

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0410

v

uSEr

Configuration of
digital input
signals

Linking external signal sources
with internal digital signals

Code is individually
adjustable in four
parameter sets

1 Motor 1

start/stop

1

Digital input X3/E1

Start motor 1

HIGH

HIGH

Stop motor 1

LOW

2 Motor 2

start/stop or
direction of
rotation

2

Digital input X3/E2

Start motor 2 or
CCW rotation

HIGH

Stop motor 2 or
CW rotation

LOW

3 Brake control

3

Digital input X3/E3

Release brake

HIGH

Apply brake

LOW

4 Reserved

255

Not assigned

...

9 Reserved

255

10 Inhibit/*release

starttec

255

Not assigned

Release starttec

HIGH

Inhibit starttec

LOW

11 External fault

255

Not assigned

No fault

HIGH

Active external
fault

LOW

12 Reset fault

255

Not assigned

LOW−HIGH edge resets fault

13 DCTRL1−PAR2/4

255

Not assigned

14 DCTRL1−PAR3/4

255

Not assigned

15 Reserved

255

Not assigned

16 Reserved

255

Not assigned

17 DCTRL1−H/Re

255

DCTRL1−H/Re = 1I

All process signals from the
bus system are set to 0.
Release of starttec via
terminal possible:

l

Place C0410/13 on the
same source as
C0410/17.

Motor start:

l

Place C0410/1 and/2 for
parameter set 2 on
digital input signals.

C0410

v

uSEr

(Cont.)

Configuration of
digital input
signals

Linking external signal sources
with internal digital signals

Code is individually
adjustable in four
parameter sets