Troubleshooting, Error messages – Lenze EDK71MMXXX−010 User Manual

Page 129

Advertising
background image

?

Troubleshooting

Error messages

129

L

EDK71MMXXX−010 DE/EN/FR 5.0

Display

Remedy

Cause

Fault

Keypad

PC

1)

Er252

A

252

Fault in mains
phase
(is generated only if
C0122 = −0−)

l

Mains phases at the
connection terminals are
reversed (incorrect direction
of rotation)

l

Connect mains cable in correct
phase relation

Er253

e

253

Fault in mains
phase
(is generated only if
C0122 = −1−)

l

Failure of one/several mains
phases

l

Check mains cable

Er254

A

254

Fault in wiring at
motor side

Short circuit in motor phases

Correct wiring

Er255

A

255

Error in power
section

l

Overvoltage, e.g. through
lightning

l

Replace starttec

OC9

A

19

l

Mains phases in connection
terminals reversed

l

Connect mains phases in correct
phase relation

LP1

A

32

Mains failure

Voltage at X1/L1, L2, L3
< 100 VAC

l

Check mains voltage

l

Check fuses

OC1

A

11

Short circuit

l

Short circuit

l

Overcurrent (8 × I

N

)

l

Find cause of short circuit; check
motor cable

l

Check brake

OC6

A

16

starttec overload

starttec overloaded (I

2

t overload)

because output current > 9.5 A

Check drive dimensioning

OC6

A

16

Overload of motor 1
(is generated only if
C0123 = −0−)

l

Motor overloaded (I

2

t

overload) through
impermissible continuous
current

l

Check drive dimensioning

Er248

e

248

Overload of motor 1
(is generated only if
C0123 = −1−)

OC7

A

17

Overload of motor 2
(is generated only if
C0123 = −0−)

l

Rated motor current
incorrectly set in C0120

l

Check setting of C0120

Er250

e

250

Overload of motor 2
(is generated only if
C0123 = −1−)

OH

A

50

Housing
temperature
> +80 °C

Ambient temperature
T

u

> +60

°C

l

Let starttec cool off and ensure
improved cooling

l

Lower ambient temperature

Housing
temperature
> +75 °C

Very dirty heat sink

Clean heat sink

Excessive currents or frequent
and extended acceleration
operations

l

Check drive dimensioning

l

Check load, replace sluggish
defective bearings, if necessary