Code table

7

EDK71MMXXX−010 DE/EN/FR 5.0

127

L

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0425

v

Delay of digital
outputs

0.00

{0.01 s}

20.00 "Debouncing" of digital

outputs

l

Switches the digital
output if the linked
signal is still active after
set time.

l

Resetting the digital
output is carried out
without delay

l

Does not affect brake
output B1, B2

1 Digital output

X3/A1

0.00

2 Digital output

X3/A2

0.00

3 Digital output

X3/A3

0.00

4 Digital output

X3/A4

0.00

C0517*

v

User menu

l

After mains connection
or in the

g

function,

the code from C0517/1
is displayed.

l

In the Lenze setting, the
User menu contains the
most important codes
for the commissioning of
a standard application

l

Enter the numbers of
the desired codes under
the subcodes

1 Memory 1

54

C0054 Apparent current of motor 1

2 Memory 2

55

C0055 Apparent current of motor 2

3 Memory 3

6

C0006 Transfer HW/hand terminal

4 Memory 4

120

C0120 Rated motor current

5 Memory 5

410

C0410 Configuration of digital input

signals

6 Memory 6

415

C0415 Configuration of digital output

signals

7 Memory 7

12

C0012 Acceleration time

8 Memory 8

423

C0423 Switch−on delay of brake

9 Memory 9

424

C0424 Switch−off delay of brake

10 Memory 10

2

C0002 Parameter set management

C0518 Service codes

Changes only through
Lenze Service!

C0519

C0520

C0600

Service codes

Changes only through
Lenze Service!

...

C0606