L

112

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0015

s

Manual setting
of operating
mode

0

0

Automatic recognition of the
operating mode

From software version
2.0 onwards
starttec recognises whether
the wiring was performed
for multi−motor operation or
for reversal of the rotation
direction. For operation with
a pole−changing motor or
with motors < 250 W, the
operating mode must be
set manually in C0015.

1

Ignoring the automatic recognition
Operating mode = operation with
one motor or multi−motor operation

2

Ignoring the automatic recognition
Operating mode = reversal or
operation with pole−changing motor

This setting is essential
when operating with
motors < 250 W in the
operation mode
"reversal"! Otherwise,
the starttec may be
destroyed.

C0016

Starting voltage
U

0

0.0

{0.1 %}

100.0

= deactivated

acceleration

time

1 Motor 1

а

а

Accepts the value from
potentiometer "U

0

"

l

If C0006 = 0, 1, 4, 5:
– Display only

l

If C0006 = 2, 3, 6, 7:
– Starting voltage

adjustable via C0016

2 Motor 2

а

а

Accepts the value from
potentiometer "T"

l

If C0006 = 0, 1, 4, 5:
– Display only

l

If C0006 = 2, 3, 6, 7:
– Starting voltage

adjustable via C0016

C0040

v

Inhibit starttec

0

starttec inhibited (CINH)

starttec can only be
released if X3/28 = HIGH

1

starttec released (CINH)

C0043

v

TRIP reset

0

Currently no fault

Reset active fault with
C0043 = 0

1

Active fault

C0052

Service code

Potentiometer "T"

Changes only through
Lenze Service!