Electrical installation

Connection of AS interface

5

EDK71MMXXX−010 DE/EN/FR 5.0

93

L

Configuration

Data bits to starttec:

In C0410 (selection 6, 7, 8), you can assign the data bits D0, D1 and D2 to internal digital signals.

Data bits from starttec:

In C0415, subcode 5 and 6, you can assign internal digital signals to data bits D0 and D1.

Example:

The starttec will be released via AS−I and a brake motor will then be started. The starttec will report
back the status of the motor and the brake via AS−I.

Data bits to starttec:

AS−I configuration

starttec
parameter setting

Comment

Bit

Command

D0

Release/inhibit starttec

C0410/10 = 6

D0 = 1:

starttec released
(requirement: terminal X3/28 = HIGH)

D0 = 0:

starttec inhibited

D1

Start/stop motor

C0410/1 = 7

D1 = 1:

Start motor

D1 = 0:

Stop motor

D2

Release/apply brake

C0410/3 = 8

D2 = 1:

Release brake

D2 = 0:

Apply brake

Data bits from starttec:

AS−I configuration

starttec
parameter setting

Comment

Bit

Message

D0

Status of motor

C0415/5 = 3

D0 = 1:

Motor is running

D0 = 0:

Motor is stopped

D1

Status of brake

C0415/6 = 5

D1 = 1:

Brake is released

D1 = 0:

Brake is applied

Advertising