Code table

EDK71MMXXX−010 DE/EN/FR 5.0

L

126

Code

IMPORTANT

Setting options

No.

Selection

Lenze

Designation

C0417

v

Configuration of
starttec status
messages (1)

Output of internal digital signals to bus

The assignment is mapped
to

l

starttec status word 1
(C0150)

l

FIF output word 1
(FIF−OUT.W1)

l

Output word 1 in CAN
object 1 (CAN−OUT1.W1)

1 Bit 0

1

Reserved

2 Bit 1

2

Reserved

3 Bit 2

3

Status of motor 1

4 Bit 3

4

Status of motor 2

5 Bit 4

5

Status of brake

6 Bit 5

6

Error in power section

7 Bit 6

7

Reserved

8 Bit 7

8

starttec released/inhibited

9 Bit 8

9

11|10|9|8 Device status

10 Bit 9

10

0011 Operation inhibited

11 Bit 10

11

0110 Operation released

12 Bit 11

12

1000 Active fault

13 Bit 12

13

Overtemperature" warning

14 Bit 13

14

Reserved

15 Bit 14

15

Reserved

16 Bit 15

16

Ready for operation

For possible internal digital signals
see C0415

C0418

v

Configuration of
starttec status
messages (2)

Output of internal digital signals to bus

The assignment is mapped
to

l

Drive controller status
word 2 (C0151)

l

FIF output word 2
(FIF−OUT.W2)

l

Output word 1 in CAN
object 2 (CAN−OUT2.W1)

1 Bit 0

255

Not assigned

... ...

...

16 Bit 15

255

Not assigned

Internal digital signals same as
C0415

C0423

Switch−on delay
of brake

0.00

0.00

{0.01 s}

20.00 Only affects brake output

X1/B1, B2

C0424

Switch−off delay
of brake

0.00

0.00

{0.01 s}

20.00

Advertising