Commissioning, Code table – Lenze EDK71MMXXX−010 User Manual
Page 114
7
Commissioning
Code table
EDK71MMXXX−010 DE/EN/FR 5.0
L
114
Code
IMPORTANT
Setting options
No.
Selection
Lenze
Designation
C0126
s
Behaviour with
communication
error
10
Monitored communication channel
You activate a combination
of monitorings by entering
the sum of the selection
values
0
All monitorings deactivated
1
Process data channel of the AIF
interface
Communication abort with
active monitoring trips TRIP
CE0
2
Internal communication between
function module to FIF and drive
controller
Communication abort with
active monitoring trips TRIP
CE5
4
Communication (Bus OFF) in
operation with system bus (CAN)
function module to FIF
Communication abort with
active monitoring trips TRIP
CE6
8
Remote parameter setting via
C0370 in operation with system
bus (CAN) function module to FIF
Communication abort with
active monitoring trips TRIP
CE7