Technical data, Rated data – Lenze EDK71MMXXX−010 User Manual

Page 79

Advertising
background image

Technical data

Rated data

2

EDK71MMXXX−010 DE/EN/FR 5.0

79

L

I

2

t tripping characteristic:

−19−

According to DIN EN 60947−4−2 (semiconductor motor control devices and starter for AC voltage)

0.01

0.1

1

10

100

1000

10000

0.02

t [s]

1.05

2

3

4

5

6

7.2

8

I/I

r

Class 10A

Class 10

Class 20

Class 30

start031

Class 10A

Tripping classes, adjustable in C0121

Class 10

= Lenze setting

Class 20

Class 30

I

Output current

I

r

Rated motor current, adjustable in C0120 or with stepping switch

Example for
Class 10:

starttec switches off with an error message if the output current I measures 4 times the set
rated motor current I

r

for approx. 13 s. (

^ 128)

)

Note!

Independent of the set tripping class, starttec always switches off if the
output current I measures 8 times the set rated motor current I

r

for approx.

20 ms.