Rockwell Automation 20-750-ENETR PowerFlexDual-Port EtherNet/IP Option Module User Manual

Page 186

Advertising
background image

186

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012

Appendix C

EtherNet/IP Objects (Adapter mode only)

5

Get

Media Counters

STRUCT of:

UDINT
UDINT
UDINT
UDINT
UDINT
UDINT
UDINT
UDINT
UDINT
UDINT
UDINT
UDINT

RX = Received, TX = Transmitted
RX frames not having integral number of octets long
RX frames not passing FCS check
TX frames having one collision
TX frames having multiple collisions
Number of times of SQE test error message
TX Frames delayed first attempt by busy medium
Collisions detected later than 512 bit-times in trans.
TX frames failing due to excessive collisions
TX frames failing due to intern MAC sublayer TX error
Times of carrier sense condition loss during trans
RX frames exceeding the maximum frame size
RX frames failing due to intern MAC sublayer RX error

6

Set

Interface Control

STRUCT of:

WORD
UINT

Control bits
Forced interface speed

7

Get

Interface Type

USINT

Type of interface; 2 = twisted-pair

10

Get

Interface Label

SHORT_STRING “1” = ENET1 network port

“2” = ENET2 network port

Attribute ID

Access Rule Name

Data Type

Description