Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012

97

Using the I/O (Adapter mode only)

Chapter 5

Figure 21 - ControlLogix Controller Example Ladder Logic Program Using a Drive Generic Profile

for Logic Command/Reference

Example Datalink Data

The Datalink data used in the example program is shown in

Figure 22

. Note that

to describe the parameters to which the Datalinks are assigned, you may want to
add descriptions to the automatically-created generic controller tags or create a
UDDT. For this example, the DL_From_Net tags were created to describe the
drive parameters to which these Datalinks are assigned. For example,
DL_From_Net_01_Stop_Mode_A indicates that option module

Host

Parameter 01 - [DL From Net 01]

is assigned to drive parameter 370 - [Stop

Mode A]. This same method applies to the DL_To_Net tags.