Rockwell Automation 20-750-ENETR PowerFlexDual-Port EtherNet/IP Option Module User Manual

Page 35

Advertising
background image

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012

35

Configuring the Option Module

Chapter 3

7.

In the BOOTP/DHCP Request History list, either double-click the
option module’s Ethernet Address (MAC) noted in step 2, or click New in
the Relation List.

The New Entry dialog box appears. In the first instance, the Ethernet
Address (MAC) is automatically entered. In the latter instance, it must be
manually entered.

8.

Edit the following:

9.

Click OK to apply the settings.

The option module appears in the Relation List with the new settings.

10.

To permanently assign this configuration to the option module, select the
device in the Relation List and click Disable BOOTP/DHCP.

When power is cycled on the option module, it will use the configuration
you assigned it and not issue new BOOTP/DHCP requests.

11.

From the File menu, choose Save to save the Relation List.

Box

Type

IP Address

(1)

(1) For definition of this term, see the

Glossary

.

A unique IP address for the option module

Host Name

Optional

Description

Optional

TIP

To enable BOOTP or DHCP for an option module that has had BOOTP/
DHCP disabled, first select the option module in the Relation List.
Then, depending on the type of server, click Enable BOOTP or Enable
DHCP and, lastly, reset the option module or power cycle the drive.