Installing the Option Module

Chapter 2

Table 1 - Adapter Mode – Drive and Option Module Start-Up Status Indications

After verifying correct operation, swing down the drive HIM bezel to its closed
position and install the drive cover. For more details on status indicator
operation, see

page 114

and

page 115

.

Item

Name

Color

State

Description

Drive STS Indicator

STS
(Status)

Green

Flashing

Drive ready but not running, and no faults are present.

Steady

Drive running, no faults are present.

Yellow

Flashing

When running, a type 2 (non-configurable) alarm condition exists –
drive continues to run. When stopped, a start inhibit condition exists
and the drive cannot be started (see drive parameter 933 - [Start
Inhibits]).

Steady

A type 1 (user configurable) alarm condition exists, but the drive
continues to run.

Red

Flashing

A major fault has occurred. Drive will stop. Drive cannot be started
until fault condition is cleared.

Steady

A non-resettable fault has occurred.

Red/
Yellow

Flashing
Alternately

A minor fault has occurred. Use drive parameter 950 - [Minor Flt
Config] to enable. If not enabled, acts like a major fault. When
running, the drive continues to run. System is brought to a stop under
system control. The fault must be cleared to continue.

Yellow/
Green

Flashing
Alternately

When running, a type 1 alarm exists.

Green/Red

Flashing
Alternately

Drive is updating.

Option Module Status Indicators—Adapter Mode

PORT

Green

Flashing

Normal operation. The option module is establishing an I/O
connection to the drive. It will turn steady green or red.

Steady

Normal operation. The option module is properly connected and
communicating with the drive.

MOD

Green

Flashing

Normal operation. The option module is operating but is not
transferring I/O data to a controller.

Steady

Normal operation. The option module is operating and transferring
I/O data to a controller.

NET A

Unlit

Off

Normal operation. DHCP is enabled or a valid IP address is not set.

Green

Flashing

Normal operation. DHCP is disabled, the option module is properly
connected, has an IP address, and is connected to an EtherNet/IP
network—but does not have an I/O connection.

Steady

Normal operation. The option module is properly connected and
communicating on the network to a controller.

NET B

Unlit

Off

Normal operation. The option module is properly connected, but is
idle.

Green

Flashing

Normal operation. The option module is properly connected, DHCP is
enabled, and the option module is transmitting on the network.

Advertising