This field is enabled when you select Static IP Address. This value will be unique

to your location. Check with your IT department to get the correct value.

Default Gateway - the network default gateway. This allows data to be passed

from one subnet to another subnet in a network.
This field is enabled when you select Static IP Address.

Search Domain - the DNS search domain. The module appends this suffix when it

attempts connecting to a FactoryTalk Historian SE, FactoryTalk Directory server,

or others services using a host name instead of an IP address.
This field is enabled when you select Static IP Address.

Primary DNS Server - the first Domain Name System (DNS) server.
This field is enabled when you select Static IP Address.

Secondary DNS Server - the second DNS server.
This field is enabled when you select Static IP Address.(optional)
Auto-Negotiate - check this box if you want Auto Negotiation to determine speed

and duplex parameters. The speed and duplex parameters must match the

parameters on the router switch.

Speed - the network speed. Ensure that this setting matches the speed set on the

switch port that your module is connected to.
This field is enabled when Auto-Negotiate is not selected.

Duplex - the duplex parameter determines how communication is sent and

received.

Select Full if you want both ends of the communication to be able to send and

receive signals at the same time.

Select Half if you still want the communication to be bidirectional, but the

signals can only flow in one direction at a time.

Ensure that this setting matches the speed set on the switch port that your module

is connected to.

After modifying the System or Network Settings, click [Save]. A popup message will

ask you to confirm your new settings. Click [Yes] or [No]. If you click [Yes], the

module will automatically reboot and the changes will take effect. If you click [No],

no changes will take effect.