Related factorytalk product issues, Factorytalk historian datalink, Factorytalk security – Rockwell Automation 1756-HIST2G Historian ME 2.1  User Manual

Page 300

Advertising
background image

F

ACTORY

T

ALK

H

ISTORIAN

ME M

ODULE

U

SER

G

UIDE

290

Related FactoryTalk Product Issues

This section describes issues related to other FactoryTalk products when they interact

with the FactoryTalk Historian ME.

FactoryTalk Historian DataLink

The FactoryTalk Historian DataLink Excel reporting tool provides a

FactoryTalk

Historian Add-In for Microsoft Excel. If you export more than 65,535 rows of

FactoryTalk

Historian ME events to DataLink using the Compressed Data (Start

Time/End Time) configuration page, Excel generates an “Output exceeds dimension”

message. This error message is generated by Excel because the amount of data

exported to the application exceeds Excel’s 65,535 row limit for data.

FactoryTalk Security

This section addresses two issues related to FactoryTalk Security.

Before connecting to FactoryTalk Security, you must install the FactoryTalk

Services Platform CPR 9 SR2 that is provided on the CD that was shipped with

your module. Select the Custom option to install the web services component.
The Custom option includes installation and configuration of Internet Information

Services (IIS). IIS must be installed on the computers that host the FactoryTalk

Directory Server.

If a user attempts to switch to FTSecurity mode but receives an “Invalid

FactoryTalk Security Server” error in the System Security page under the
Configure Historian

tab, use this procedure to resolve the issue:

1. From Control Panel > Administrative Tools, run the IIS Admin Manager.

Expand the virtual directory FactoryTalk/Security/Web Service, then right click

on FactoryTalk\Security\WebService\200810.asmx to select Browse. You can

now test the FactoryTalk Security (FTSecurity) service interfaces.

2. From Control Panel > Administrative Tools, run Services.

Change the startup type for ASP.NET State Service to automatic. Ensure that the

asp.net service is started. This deploys the web service to the following URL:

See the FactoryTalk Services Platform CPR 9 SR2 Release Notes for IIS installation
details.