FactoryTalk Historian SE for data aggregation when long-term storage is

required.
By applying Compression and Exception Filtering, you can significantly improve

archive space from approximately two to ten times, depending on variables such

as how much the data varies between scans. To estimate archive performance with

and without Compression and Exception Filtering, can use a typical factor of 5.
Use the table below to estimate performance impact. Note that Compression and

Exception Filtering data storage information in this table is an estimate. Actual

compressed data storage ranges will vary with the volatility of the data collected.

Sample Application

Estimate

1GB Module

2GB Module

2500 events per second without

Compression or Exception Filtering

4 hours

14 hours

2500 events per second with

Compression and Exception Filtering

1 day

3 days

500 events per second with

Compression

and Exception Filtering

5 days

2 weeks

100 events per second with

Compression

and Exception Filtering

1 month

3 months

2500 events per minute without

Compression or Exception Filtering

10 days

1 month

2500 events per minute with

Compression and Exception Filtering

2 months

6 months

500 events per minute with

Compression

and Exception Filtering

10 months

2.5 years

100 events per minute with

Compression

and Exception Filtering

4 years

10+ years