Controlbus statistics – Rockwell Automation 1756-HIST2G Historian ME 2.1  User Manual

Page 191

Advertising
background image

10 • U

SING

W

EB

D

IAGNOSTICS

181

The Controller Statistics page provides information about Logix Controllers in the

chassis.

Slot Number - the chassis slot in which the Logix Controller is installed.

Application Name - the name of the program running on the Logix Controller.

Fault Status - the Logix Controller’s current fault status is one of the following:

No Fault

Minor Fault

Major Fault

Total Active Points - the total number of active tags between the module and this

controller.

Point Event Rate/Sec - the number of tag reads from this controller, per second,

accumulated over a rolling 10 second period. Therefore, the value is the average

tag reads per second over the previous 10 seconds.

Point Failure Rate/Sec - the number of tag read failures from this controller, per

second, accumulated over a rolling 10 second period. Therefore, the value is the

average tag read failures per second over the previous 10 seconds.

CPU Loading - the controller's CPU utilization in tenths of a percent. For

example, the range of 0 - 100 representing 0 to 100%.

ControlBus Statistics

The ControlBus Statistics page provides general status and diagnostic-related

information about the ControlLogix backplane. To access the page, click Hardware

in the top navigation bar of the Web Diagnostics interface, and then click
ControlBusStatistics

in the left navigation bar.

Advertising
This manual is related to the following products: