Resetting the Security Mode
The results of resetting security depends on the Security mode you have configured
for the module.
If the module was configured for FactoryTalk Security, clicking [Security Reset] will
result in the following:
Data Collection stops immediately.
The module is shut down and restarted using Native security.
The administrative piadmin user and users that were created in Native security
mode are retained.
The piadmin user password is set to blank.
If the module was configured for Native security, clicking [Security Reset] will reset
the piadmin user password to blank and prompt the user to log into the FactoryTalk
Historian ME web interface.
Resetting Native security does not require rebooting the module.