Resetting the security mode – Rockwell Automation 1756-HIST2G Historian ME 2.1  User Manual

Page 161

Advertising
background image

8 • A

DMINISTERING

THE

M

ODULE

151

Resetting the Security Mode

The results of resetting security depends on the Security mode you have configured

for the module.

If the module was configured for FactoryTalk Security, clicking [Security Reset] will

result in the following:

Data Collection stops immediately.

The module is shut down and restarted using Native security.

The administrative piadmin user and users that were created in Native security

mode are retained.

The piadmin user password is set to blank.

If the module was configured for Native security, clicking [Security Reset] will reset

the piadmin user password to blank and prompt the user to log into the FactoryTalk

Historian ME web interface.
Resetting Native security does not require rebooting the module.