ClearOne Converge Pro User Manual

Page 268

Advertising
background image

263

AVG – Adaptive Volume Gain

This command sets the maximum gain setting that the algorithm will not exceed.

Command Form

:

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupsAndChannels

-

Group

Group

1

23 (J)

-

Value

Signed Short

2

0.00 to +18.00
(Null to query in text)

dB

AVR – Adaptive Volume Reference

This command selects/reports the microphone or expansion bus reference channel to be used for adaptive
volume tracking on a power amplifier channel.

Command Form

: DEVICE AVR [CHANNEL] [GROUP]

Argument Type

Size

Values

Units

Channel

Channel

1

(M) 1-8
(E) 1-18
(Null to query in text)

-

Group

Group

1

3, 6 (M or E)

-

AVRT – Adaptive Volume Ratio

This command sets the ratio at which gain will be automatically applied based upon the ambient level in the
reference microphone. Example: A 1:1 setting would apply 1 dB of gain for every 1dB rise in ambient level of the
reference microphone up to the Max Gain setting.

Command Form

: DEVICE AVRT <Channel><Group> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Value

Unsigned Short

2

0 = 2:1
1 = 1:1
2 = 1:2
(Null to query in text)

Ratio

AVT – Adaptive Volume Threshold

This command sets the level at which the adaptive volume algorithm will be activated. This value is referenced to
the noise floor of the channel and the target above ambient for the adaptive volume to reach.

Command Form

:

Device AVT <Channel><Group> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Value

Signed Short

2

-80.00 to 0.00
(Null to query in text)

-

BAUD – Baud Rate

This command selects/reports the baud rate of the serial port.

Command Form

: DEVICE BAUD [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

9600, 19200, 38400, 57600, 115200
(Null to query in text)

-