295

PAEQSET – PA EQ Filter Set

This command sets/reports the EQ Level for a given band in the filter bank

Command Form

: DEVICE PAEQEN <Channel> <Group> <Band> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

23 (J)

-

Band

Unsigned
Short

2

1 = 32.25 Hz
2 = 62.5 Hz
3 = 125.0 Hz
4 = 250.0 Hz
5 = 500.0 Hz
6 = 1000.0 Hz
7 = 2000.0 Hz
8 = 4000.0 Hz
9 = 8000.0 Hz
10 = 16000.0 Hz

Hz

Value

Signed
Float

4

-12.00 – 12.00
(Null to query in text)

dB

PAFLT – PA Fault

This indicates one of the power amplifier channels is in a FAULT condition. This is Read-Only, and is
automatically generated if a fault occurs.

Command Form

: DEVICE PAEQEN [Bitmap]

Argument Type

Size

Values

Bitmap

Hexadecimal Integer 4

PAIMPED – PA Output Impedance

This command selects the output impedance for the PA channel to be either 8 ohms or 70/100V.

Command Form

: DEVICE PIAMPED <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

23 (J)

-

Value

Unsigned
Short

2

0 = 8 ohms
1 = 70/100V
(Null to query in text)

-

PALEN – PA Limiter Enable

This command changes enables the Limiter on a power amplifier channel.

Command Form

: DEVICE PALEN <Channel> <Group> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

23 (J)

-

Value

Unsigned Short

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-