41

CONVERGE USB

Refer to the following diagrams and descriptions describe the CONVERGE USB connections and controls when
used as an USB interface and as and E-bus extender.

CONVERGE USB Interface Connections

Connect each CONVERGE USB unit to the site via the E-bus connections.

E-bus LINK IN from Stack

E-bus LINK OUT

(Not required if unit is at end of stack)

USB Connection to PC/Laptop or COLLABORATE Room

(Not required if used as an E-bus Extender)

12V DC

Power

Input

Terminal Block for Channel Selection

(Not required if used as an E-bus Extender)

COLLABORATE Room

VC Endpoint

or

Laptop/PC Running

UC Application

USB

Audio

Transmit and Receive

E-bus

From

LINK Out

E-bus To

LINK In

CONVERGE USB

CONVERGE Pro Unit

The E-bus channels upon which the Tx/Rx audio will be available is determined by the jumpers placed in the
Channel Selection Terminal Block.

Tx channel - K

Rx channel - L

Tx channel - M

Rx channel - N

Tx channel - O

Rx channel - P

Tx channel - Q

Rx channel - R

No

Connector

Routing the CONVERGE USB Interface Connections

Using CONVERGE Console, route each CONVERGE USB Tx/Rx signal within the site to match the E-bus
connections as selected by the terminal block. This is done on the Matrix screen for the site.
In the example below a terminal block jumper is between pins 1 and 6, so the CONVERGE Pro channels are M for
transmit and N for receive. These must then be routed to the desired inputs and outputs. The following two screen
captures show audio from the CONVERGE USB on Channel M going to Output 8, and Channel N receiving audio
from Input 9 then sending it to the CONVERGE USB.

Tx channel - M

Rx channel - N