ClearOne Converge Pro User Manual

Page 278

Advertising
background image

273

DFLTM – Default Meter

This command selects/reports the setting of the default meter on the front panel.

Command Form

: DEVICE DFLTM [Channel Group Position]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

(Null to query in text)

-

Group

Group

1

1, 2, 3, 7, 16, 17 (I, O, M, L, T, R)

-

Position

Meter Type

2

1 – 4, as applicable for group
See

Meter Type Definitions

-

DIAG – Diagnostic Commands

This command is used to return status and diagnostic information. It is intended to be used as a text command
only. This is a query only command.

Command Form

: DEVICE DIAG <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

23 (J)

-

Value

Unsigned
Short

2

0 = List of current commands
(J) Power Amp
1 = Fan/Temp
2 = Noise Gate
3 = Feedback Nodes

-

Information

String

80

Diagnostic String
(ALWAYS NULL IN TEXT)

-

DIAL – DTMF Dialing

This command dials a DTMF sequence or reports back the last sequence dialed.

Command Form

: DEVICE DIAL <Channel> [Number]

Argument

Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

17 (R)

-

Reserved

2

0

-

Number

String

40

1 – 40 Chars of ‘0’ – ‘9’, ‘*’, ‘#’, ‘,’
(Null to query last number dialed in text)

-

DID – Device ID

This command reports the device id. This command is read only except through the front panel.

Command Form

: DEVICE DID [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

See

Type And Device IDs

(Null sent in text, Value returned)

-

DTMFLVL – DTMF Tone Level

This command selects/reports the DTMF tone level.

Command Form

: DEVICE DTMFLVL <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

17 (R)

-

Value

Signed Float

2

-12.00 – 12.00
(Null to query in text)

dB

Advertising