304

RXBSTEN – Receive Boost Enable

This command selects/reports the receive boost status.

Command Form

: DEVICE RXBSTEN <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

17 (R)

-

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

SERECHO – Serial Echo

This command selects/reports the serial echo of the RS-232 port.

Command Form

: DEVICE SERECHO [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

NOTE: The unit will return the updated state of the last selection in the same form as the

command.

SFTYMUTE – Safety Mute

This command selects/reports the state of the safety mute. Safety mute holds all outputs in a muted state. It used
for syncing to a site document to avoid feedback or blown speakers until the unit is in a settled state.

Command Form: DEVICE SFTYMUTE [Value]

Argument Type

Size

Values

Units

Value

Channel

4

0 = off
1 = on
2 = toggle
(Null to query in text)

-

SIGGEN – Signal Generator

This command selects/reports of the signal generator activation.

Command Form

: DEVICE SIGGEN [Channel Group Type Amplitude Frequency]

Argument

Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

(Null to query in text)

-

Group

Group

1

1, 3, 7 (I, M, L)

-

Type

Unsigned Integer

2

1 = Pink Noise
2 = White Noise
3 = Tone

-

Amplitude

Signed Float

4

-60.00 – 20.00

dB

Frequency

Unsigned Float

4

Type 1 – 2

0 (Null in text)

Hz

Type 3

20.00 – 20000.00

SIGGENEN – Signal Generator Enable

This command selects/reports of the signal generator activation.

Command Form

: DEVICE SIGGENEN [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-