40 connect cobranet/avb connections and controls, Connect cobranet and connect avb connections, Connect cobranet and connect avb control – ClearOne Converge Pro User Manual

Page 45

Advertising
background image

40

CONNECT Cobranet/AVB Connections and Controls

Refer to the following diagrams and descriptions for CONNECT CobraNet/AVB connections and controls.

CONNECT CobraNet and CONNECT AVB Connections

Set each CONNECT CobraNet and CONNECT AVB unit to a unique ID using the Device ID selector rotary switch
on the back of the unit. (Range 0-7) Each CONNECT unit in any site needs a unique Device ID. Only 8 units are
allowed in any site.

Ethernet LAN

Network 1

CONVERGE Pro/SR

CONNECT

Network Bridge

CONNECT

Network Bridge

Ethernet LAN

Network 2

CobraNet

CONNECT

Network Bridge

CONNECT

Network Bridge

Connecting CONVERGE Pro/SR units in different

rooms that are on different networks using

multiple CobraNet

and AVB network bridges

AVB

CobraNet

AVB

AVB

CobraNet

Link IN

Link IN

Link OUT

Link IN

Link IN

AVB

Network

Connection

AVB

Network

Connection

CobraNet

Network

Connection

CobraNet

Network

Connection

CONVERGE Pro/SR

CONVERGE Pro/SR

Device ID

Switch

E-bus LINK IN from Stack

E-bus LINK OUT

(Not required if the bridge

is at the end of the stack)

Bridge connection

to Ethernet Network

(CobraNet shown)

5V DC

Power

Input

CONNECT CobraNet and CONNECT AVB Control

The CONNECT CobraNet and the CONNECT AVB network audio bridges are controlled mainly through
CONVERGE Console where configuration is made and device identification (set matching the Device ID switch) is
established in the stack.