ClearOne Converge Pro User Manual

Page 276

Advertising
background image

271

COMPSEL – Compression Select

This command selects/reports the compressor activation.

Command Form

: DEVICE COMPSEL <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

5 (P)

-

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

COUNTRY – Country Selection

This command sets / reports the country for telco compliance purposes.

Command Form

: DEVICE COUNTRY [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

1 = US / Canada
2 = Europe
3 = Mexico
4 = Australia
5 = South Africa
6 = Japan
7 = Brazil
8 = South Korea
9 = China
10 = Singapore
11 = Taiwan
12 = New Zealand
13 = India
14 = Hong Kong
15 = Malaysia
16 = Argentina
(Null to query in text)

-

CTRLMASTER – Control Master Mode

This command reports the mode of the unit for SNMP control.

Command Form

: DEVICE CTRLMASTER [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

1 = Master
2 = Slave
(Null to query in text)

-

DECAY – Decay Adjust

This command selects/reports the setting of the decay rate.

Command Form

: DEVICE DECAY <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

3 (M)

-

Value

Unsigned Integer

2

1 = Slow
2 = Medium
3 = Fast
(Null to query in text)

-

DEFAULT – Default The Unit

Sets the unit to factory defaults. There is no query for this command.

Command Form

: DEVICE DEFAULT

No Arguments