ClearOne Converge Pro User Manual

Page 295

Advertising
background image

290

MLINE – Mic / Line Coarse Gain Setting

This command selects/reports the setting of coarse gain.

Command Form

: DEVICE MLINE <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

3 (M)

-

Value

Unsigned Integer

2

0 = 0 dB
7 = 7 dB
14 = 14 dB
21 = 21 dB
28 = 28 dB
35 = 35 dB
41 = 41 dB
50 = 50 dB
56 = 56 dB
(Null to query in text)
(No other values are valid and accepted)

-

MMAX – Maximum Number of Microphones

This command selects/reports the maximum number of microphones for a Gating Group.

Command Form

: DEVICE MMAX <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

4 (G)

-

Value

Unsigned Integer

2

0 = Unlimited
1 - 8 = Maximum # of Mics
(Null to query in text)

-

MODEL – Model Identification Label

This command selects/reports the model identification label of the specified channel.

Command Form

: DEVICE MODEL <Channel> <Group> <Reserved>[Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

1, 2, 3, 7
(I, O, M, L, D)

-

Reserved

Unsigned
Integer

2

0

-

Label

String

16

1-16 characters
CLEAR = clear the label
(Null to query in text)

dB

Advertising