Fcfabricname, Fcelementname, Fcfemodulecapacity – Dell POWEREDGE M1000E User Manual

Page 114: Fcfemoduletable, Fcfemoduleentry, Fcfemoduleindex, Fcfemoduledescr, Fcfemoduleobjectid, Fcfemoduleoperstatus, Fcfemodulelastchange

Advertising
background image

94

Fabric OS MIB Reference

53-1002750-01

fcFeConfig group

4

Implementation of this group is mandatory.

TABLE 33

Object and OID

Access

Description

fcFabricName
1.3.6.1.3.42.2.1.1.1

Read only

The Name_Identifier of the fabric to which this fabric element
belongs.
This object returns the WWN of the primary switch in the fabric.

fcElementName
1.3.6.1.3.42.2.1.1.2

Read only

The Name_Identifier of the fabric element.
This object returns the WWN of the switch.

fcFeModuleCapacity
1.3.6.1.3.42.2.1.1.3

Read only

The maximum number of modules in the fabric element, regardless of
their current state.
The Brocade 12000, 24000, and 48000 directors do not support this
MIB variable.
The Value for fcFeModuleCapacity is always one for all the supported
switches.

fcFeModuleTable
1.3.6.1.3.42.2.1.1.4

Not
accessible

A table that contains, one entry for each module in the fabric element,
information of the modules.

fcFeModuleEntry
1.3.6.1.3.42.2.1.1.4.1

Not
accessible

An entry containing the configuration parameters of a module.

fcFeModuleIndex
1.3.6.1.3.42.2.1.1.4.1.1

Read only

Identifies the module within the fabric element for which this entry
contains information. This value is never greater than
fcFeModuleCapacity.

fcFeModuleDescr
1.3.6.1.3.42.2.1.1.4.1.2

Read only

A textual description of the module. This value should include the full
name and version identification of the module. It should contain
printable ASCII characters.
Refer to

“sysDescr”

on page 33.

fcFeModuleObjectID
1.3.6.1.3.42.2.1.1.4.1.3

Read only

The vendor’s authoritative identification of the module. This value
might be allocated within the SMI enterprises subtree (1.3.6.1.4.1)
and provides a straight-forward and unambiguous means for
determining what kind of module is being managed.
For example, this object could take the value 1.3.6.1.4.1.99649.3.9
if vendor “Neufe Inc.” was assigned the subtree 1.3.6.1.4.1.99649,
and had assigned the identifier 1.3.6.1.4.1.99649.3.9 to its
‘FeFiFo-16 PlugInCard.’
Refer to

“sysObjectID”

on page 33.

fcFeModuleOperStatus
1.3.6.1.3.42.2.1.1.4.1.4

Read only

Indicates the operational status of the module:

online (1) - The module is functioning properly.

offline (2) - The module is not available.

testing (3) - The module is under testing.

faulty (4) - The module is defective in some way.

fcFeModuleLastChange
1.3.6.1.3.42.2.1.1.4.1.5

Read only

Contains the value of

“sysUpTime”

when the module entered its

current operational status. A value of 0 indicates that the operational
status of the module has not changed since the agent last restarted.

fcFeModuleFxPortCapacity
1.3.6.1.3.42.2.1.1.4.1.6

Read only

The number of Fx_Port that can be contained within the module.
Within each module, the ports are uniquely numbered in the range
from 1 to fcFeModuleFxPortCapacity, inclusive; however, the numbers
are not required to be contiguous.

fcFeModuleName
1.3.6.1.3.42.2.1.1.4.1.7

Read only

The Name_Identifier of the module.
The return value is the WWN of the switch.