Swfcporttype, Swfcportphystate, Swfcportopstatus – Dell POWEREDGE M1000E User Manual

Page 173: Swfcportadmstatus

Advertising
background image

Fabric OS MIB Reference

153

53-1002750-01

Fibre Channel port group

6

swFCPortType
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.2

Read only

The type of ASIC for the switch port.
Possible values are:

stitch (1)

flannel (2)

loom (3) (Brocade 2000 series)

bloom (4) (Valid value for Brocade 3250, 3850, 3900, 12000,
24000)

rdbloom (5)

wormhole (6)

other (7) (Valid value for Brocade 200E, 4012, 4100, 4900,
7500, 7600, 48000, 300, 5100 and 5300)

unknown (8)

swFCPortPhyState
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.3

Read only

The physical state of the port.
Possible values are:

noCard (1) - No card is present in this switch slot.

noTransceiver (2) - No Transceiver module in this port
(Transceiver is the generic name for GBIC, SFP, and so on).

laserFault (3) - The module is signaling a laser fault (defective
GBIC).

noLight (4) - The module is not receiving light.

noSync (5) - The module is receiving light but is out of sync.

inSync (6) - The module is receiving light and is in sync.

portFault (7) - The port is marked faulty (defective GBIC, cable, or
device).

diagFault (8) - The port failed diagnostics (defective G_Port or
FL_Port card or motherboard).

lockRef (9) - The port is locking to the reference signal.

validating (10) - The module is being validated.

invalidModule (11) - The module is invalid.

noSigDet (14) - No Signal is detected in the port.

unknown (255) - The module is unknown.

swFCPortOpStatus
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.4

Read only

The operational status of the port.
Possible values are:

unknown (0) - The port module is physically absent.

online (1) - User frames can be passed.

offline (2) - No user frames can be passed.

testing (3) - No user frames can be passed.

faulty (4) - The port module is physically faulty.

swFCPortAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.6.2
.1.5

Read-write The desired state of the port. A management station might place the

port in a desired state by setting this object accordingly.
Based on the port status, this OID returns one of the following:

Online - When queried port is online.

Offline - When queried port is offline.

Faulty - When port is in faulty state.

The following values can be used to set this object:

Online - To change port's state to Online.

Offline - To change port's state to Offline.

TABLE 50

Object and OID

Access

Description

Advertising