98

Fabric OS MIB Reference

53-1002750-01

fcFeOp group

4

fcFxPortPhysOperStatus
1.3.6.1.3.42.2.1.2.3.1.4

Read only

The current operational status of the Fx_Port:

online (1) Log in might proceed.

offline (2) Log in cannot proceed.

testing (3) Port is under test.

link-failure (4) Failure after online/testing.
The testing state (3) indicates that no operational frames can be
passed. If fcFxPortPhysAdminStatus is offline (2), then
fcFxPortPhysOperStatus should be offline (2). If
fcFxPortPhysAdminStatus is changed to online (1), then
fcFxPortPhysOperStatus should change to 1 (online) if the Fx_Port is
ready to accept fabric login request from the attached Nx_Port; it should
proceed and remain in the link-failure state (4) if and only if there is a
fault that prevents it from going to the online state (1).

fcFxPortPhysLastChange
1.3.6.1.3.42.2.1.2.3.1.5

Read only

The value of sysUpTime at the time the Fx_Port entered its current
operational status. A value of 0 indicates that the Fx_Port’s operational
status has not changed since the agent last restarted.

fcFxPortPhysRttov
1.3.6.1.3.42.2.1.2.3.1.6

Read only

The Receiver_Transmitter_Timeout value of the Fx_Port. This is used by
the receiver logic to detect Loss of Synchronization.

fcFxlogiTable
1.3.6.1.3.42.2.1.2.4

Not
accessible

This table contains one entry for each Fx_Port in the fabric element, and
the Service Parameters that have been established from the most
recent fabric login, whether implicit or explicit.

fcFxlogiEntry
1.3.6.1.3.42.2.1.2.4.1

Not
accessible

An entry containing service parameters established from a successful
fabric login.

fcFxlogiModuleIndex
1.3.6.1.3.42.2.1.2.4.1.1

Read only

Identifies the module containing the Fx_Port for which this entry
contains information.

fcFxlogiFxPortIndex
1.3.6.1.3.42.2.1.2.4.1.2

Read only

Identifies the Fx_Port within the module. This number ranges from 1 to
the value of fcFeModulePortCapacity for the associated module. The
value remains constant for the identified Fx_Port until the module is
re-initialized.

fcFxlogiNxPortIndex
1.3.6.1.3.42.2.1.2.4.1.3

Read only

The object identifies the associated Nx_Port in the attachment for which
the entry contains information.

fcFxPortFcphVersionAgree
d
1.3.6.1.3.42.2.1.2.4.1.4

Read only

The version of FC-PH that the Fx_Port has agreed to support from the
fabric login.

fcFxPortNxPortBbCredit
1.3.6.1.3.42.2.1.2.4.1.5

Read only

The total number of buffers available for holding Class 1
connect-request Class 2 or Class 3 frames to be transmitted to the
attached Nx_Port. It is for buffer-to-buffer flow control in the direction
from Fx_Port to Nx_Port. The buffer-to-buffer flow control mechanism is
indicated in the respective fcFxPortBbCreditModel.

fcFxPortNxPortRxDataFiel
dSize
1.3.6.1.3.42.2.1.2.4.1.6

Read only

The Receive Data Field Size of the attached Nx_Port. This is a binary
value that specifies the largest Data Field Size for an FT_1 frame that
can be received by the Nx_Port. The value is a number of bytes in the
range 128 to 2112, inclusive.

fcFxPortCosSuppAgreed
1.3.6.1.3.42.2.1.2.4.1.7

Read only

Indicates that the attached Nx_Port has requested the Fx_Port for the
support of classes of services and the Fx_Port has granted the request.

TABLE 34

Object and OID

Access

Description