Connunitsensorstat uschange, Connunitportstatus change – Dell POWEREDGE M1000E User Manual

Page 255

Advertising
background image

Fabric OS MIB Reference

235

53-1002750-01

FibreAlliance MIB traps

9

connUnitSensorStat
usChange
1.3.6.1.3.94.0.5

connUnitSensorStatus Overall status of the connectivity unit has changed.

This trap is generated whenever the status of the sensors (like
fan, power supply, temperature) present in the connectivity unit
changes.
Sample trap output for Fabric OS v6.1.0.

connUnitSensorStatus.16.0.0.96.105.144.109.13
6.0.0.0.0.0.0.0.0.7 = failed(5)

For information on configuring thresholds that generate these
traps, refer to the Fabric Watch Administrator’s Guide.

connUnitPortStatus
Change
1.3.6.1.3.94.0.6

connUnitPortStatus
connUnitPortState

Overall status of the connectivity unit changed. Recommended
severity level (for filtering)- alert.
This trap sends the instance of connUnitPortName as part of the
trap; the instance string is NULL, if the port name is not defined
for the specified port.
Sample trap output for Fabric OS v6.1.0.

connUnitPortStatus.16.0.0.96.105.144.109.136.
0.0.0.0.0.0.0.0.29 = ready(3)
connUnitPortState.16.0.0.96.105.144.109.136.0
.0.0.0.0.0.0.0.29 = online(2)
connUnitPortName.16.0.0.96.105.144.109.136.0.
0.0.0.0.0.0.0.29 = test
For more information, refer to

“swFCPortScn”

.

TABLE 83

Trap name and OID

Variables

Description

Advertising