6

swSensorValue
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.4

Read only

The current value (reading) of the sensor.
The value -2147483648 represents the maximum value of integer
value; it also means that the sensor does not have the capability to
measure the actual value. In v2.0, the temperature sensor value is
in Celsius, the fan value is in RPM (revolutions per minute), and the
power supply sensor reading is unknown.
The unknown value -2147483648 indicates the maximum value of
integer value.

swSensorInfo
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.5

Read only

Additional information on the sensor. It contains the sensor type
and number, in textual format; for example:
SLOT #0: TEMP #3
FAN #1
Power Supply #1
Return values for the Brocade 12000, 24000, and 48000 directors
depend upon the configuration of your system.

swTrackChangesInfo
1.3.6.1.4.1.1588.2.1.1.1.1.23

Read only

Track changes string; for trap only.
If there are no events to track, the default return value is “No event
so far.”
If there are events to track, the following are valid return values:

Successful log in

Unsuccessful log in

Logout

Configuration file change from task [name of task]

Track-changes on

Track-changes off

swID
1.3.6.1.4.1.1588.2.1.1.1.1.24

Read only

With VF-enabled fabric, the number of switches will be 0 to 128.

swEtherIPAddress
1.3.6.1.4.1.1588.2.1.1.1.1.25

Read only

Supported in Fabric OS v6.2.0 and later releases.
The IP address of the Ethernet interface of this switch.

swEtherIPMask
1.3.6.1.4.1.1588.2.1.1.1.1.26

Read only

The IP mask of the Ethernet interface of this switch.

swFCIPAddress
1.3.6.1.4.1.1588.2.1.1.1.1.27

Read only

The IP address of the FC interface of this switch.

swFCIPMask
1.3.6.1.4.1.1588.2.1.1.1.1.28

Read only

The IP mask of the FC interface of this switch.

swIPv6Address
1.3.6.1.4.1.1588.2.1.1.1.1.29

Not
accessible

The IPv6 address. This object is not accessible.

swIPv6Status
1.3.6.1.4.1.1588.2.1.1.1.1.30

Not
accessible

The current status of the IPv6 address. This object is not
accessible.

swModel
1.3.6.1.4.1.1588.2.1.1.1.1.31

Read only

Indicates whether the switch is 7500 or 7500E.

swTestString
1.3.6.1.4.1.1588.2.1.1.1.1.32

Not
accessible

Presence of this string represents test trap.

swPortList
1.3.6.1.4.1.1588.2.1.1.1.1.33

Not
accessible

This string represents the list of ports and its WWN when the ports