Entphysicalcontainedin, Entphysicalclass – Dell POWEREDGE M1000E User Manual
Page 129
 
Fabric OS MIB Reference
109
53-1002750-01
Physical entity group
5
entPhysicalContainedIn
1.3.6.1.2.1.47.1.1.1.1.4
Read only
The value of entPhysicalIndex for the physical entity that “contains” this 
physical entity. A value of 0 indicates this physical entity is not 
contained in any other physical entity. Note that the set of containment 
relationships define a strict hierarchy; that is, recursion is not allowed.
In the event a physical entity is contained by more than one physical 
entity (for example, double-wide modules), this object should identify 
the containing entity with the lowest value of entPhysicalIndex.
Value 0 for chassis entry. All containers have ContainedIn set to 1. All 
FRUs are contained in their respective slot container entries.
entPhysicalClass
1.3.6.1.2.1.47.1.1.1.1.5
Read only
An indication of the general hardware type of the physical entity.
An agent should set this object to the standard enumeration value that 
most accurately indicates the general class of the physical entity, or the 
primary class if there is more than one.
If no appropriate standard registration identifier exists for this physical 
entity, then the value 
other (1) is returned. If the value is unknown by this agent, then the 
value unknown (2) is returned.
Brocade 300 switches can have the following hierarchy of physical 
objects:
•
Chassis: One entry (one row)
•
Container: One entry for each FRU slot (one blade, one power 
supply, three fans)
•
Module: One entry for blades, one entry for power supply, and 
three entries for fans
Brocade 5100 switches can have the following hierarchy of physical 
objects:
•
Chassis: One entry (one row)
•
Container: One entry for each FRU slot (one blade, two power 
supplies, two fans)
•
Module: One entry for blades, two entries for power supplies, and 
two entries for fans
Brocade 5300 switches can have the following hierarchy of physical 
objects:
•
Chassis: One entry (one row)
•
Container: One entry for each FRU slot (one blade, two power 
supplies, three fans)
•
Module: One entry for blades, two entries for power supplies, and 
three entries for fans
TABLE 39
Object and OID
Access
Description