Swbeaconadmstatus, Swdiagresult, Swnumsensors – Dell POWEREDGE M1000E User Manual

Page 165: Swsensortable, Swsensorentry, Swsensorindex, Swsensortype, Swsensorstatus, Swsensorstatus swsensorindex swsensortype

Advertising
background image

Fabric OS MIB Reference

145

53-1002750-01

Switch system group

6

swBeaconAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.1.19

Read-write

The desired status of the switch beacon.
Possible values are:

on (1) - The LEDs on the front panel of the switch run
alternately from left to right and right to left. Set the color to
yellow.

off (2) - Set each LED to its regular status, indicating color and
state.

swDiagResult
1.3.6.1.4.1.1588.2.1.1.1.1.20

Read only

The result of the power-on startup test (POST) diagnostics.
Possible values are:

sw-ok (1) - The switch is okay.

sw-faulty (2) - The switch has experienced an unknown fault.

sw-embedded-port-fault (3) - The switch has experienced an
embedded port fault.

swNumSensors
1.3.6.1.4.1.1588.2.1.1.1.1.21

Read only

The number of sensors inside the switch.
The Brocade DCX value is between 1 and 57 (temperature =50, fan
= 3, power supply = 4). The value might vary depending on the
switch model. For Fabric OS v6.1.0, if no sensor is available, this
variable is assigned the value -1.

swSensorTable
1.3.6.1.4.1.1588.2.1.1.1.1.22

Not
accessible

Table of sensor entries.

Table 46

lists the sensors on the Brocade switches.

The sensors on the switches vary based on the blades. For the
exact count of temperature sensors, refer to

Table 47

.

swSensorEntry
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1

Not
accessible

An entry of the sensor information.

swSensorIndex
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.1

Read only

The index of the sensor.
The values are 1 through the value in swNumSensors

swSensorType
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.2

Read only

The type of sensor.

swSensorStatus
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.3

Read only

The current status of the sensor.
Possible values are:

unknown (1)

faulty (2)

below-min (3) - The sensor value is below the minimal
threshold.

nominal (4)

above-max (5) - The sensor value is above the maximum
threshold.

absent (6) - The sensor is missing.

For Temperature, valid values include 3 (below-min), 4 (nominal),
and 5 (above-max).
For Fan, valid values include 3 (below-min), 4 (nominal), and 6
(absent).
For Power Supply, valid values include 2 (faulty), 4 (nominal), and 6
(absent).

TABLE 45

Object and OID

Access

Description

Advertising