Firmware upgrades and enabled traps

1

Firmware upgrades and enabled traps

The pre-Fabric OS v4.4 firmware had trap group level settings (for example, traps were turned on
and off as a group). In Fabric OS v4.4 or later, you can turn on and off traps individually within a
trap group. When you upgrade to the Fabric OS v4.4 firmware or later, by default the individual
traps are turned off even if the corresponding trap group was enabled before upgrading. You must
use the snmpconfig command to turn on explicitly the individual traps within each trap group.

Fabric OS commands for configuring SNMP

Use the following commands (

Table 5

) to configure MIBs in the Fabric OS. For procedures for

configuring SNMP on the Brocade switches, refer to the Fabric OS Administrator’s Guide.

For more information about the commands, either refer to

Table 6

or the Fabric OS Command

Reference.

FE-MIB

No

Disabled in Access Gateway because the conventions are specific to
fabric switches.

CPQ-Rack MIB

Limited

Supported on embedded switches only.

FCIP MIB

No

Disabled in Access Gateway because the conventions are specific to
fabric switches.

iSCSI MIB

No

Disabled in Access Gateway because the conventions are specific to
fabric switches.

IF-MIB

Yes

Supported in Access Gateway.

BD-MIB

Yes

Supported for F-ports.

IEEE 802.3 LAG MIB

No

Supported in Access Gateway.

IEEE 802.1x PAE MIB

No

Supported in Access Gateway.

LLDP MIB

No

Supported in Access Gateway.

BRIDGE-MIB

No

Supported in Access Gateway.

RMON-MIB

Yes

Supported in Access Gateway.

FA-Ext

Yes

Supported in Access Gateway.

SNMPv2 MIB

Yes

Supported in Access Gateway.

TABLE 4

Access Gateway MIB support (Continued)

MIB name

Supported

Description

TABLE 5

Commands for configuring SNMP

Command

Description

snmpConfig

This command has all the features of the existing agtcfg* commands; in addition, it has
SNMPv3 configuration parameters.
Enhanced in Fabric OS v6.3.0 to support SNMP Informs for SNMPv3 users.
Enhanced in Fabric OS v6.4.0 to support option-based mibcapability behavior.

snmpTraps

This command supports the SNMP notification generator feature, Notification generator
framework has been implemented to send various SNMP traps.