Connunitseventtime, Connuniteventseverity, Connuniteventtype – Dell POWEREDGE M1000E User Manual

Page 242: Connuniteventobject, Connuniteventdescr

Advertising
background image

222

Fabric OS MIB Reference

53-1002750-01

Connectivity unit group

9

connUnitSEventTime
1.3.6.1.3.94.1.11.1.5

Read only

This is the sysuptime time stamp when the event occurred.

connUnitEventSeverity
1.3.6.1.3.94.1.11.1.6

Read only

The event severity level. The mapping between error log severity level
and this variable is:
Error log

FA-MIB

none (0)

unknown (1)

Critical (1)

critical (4)

Error (2)

error (5)

Warning (3)

warning (6)

Informational (4)

info (8)

Debug (5)

debug (9)

For more information about severity, refer to

“FcEventSeverity”

in

Table

74

on page 203.

connUnitEventType
1.3.6.1.3.94.1.11.1.7

Read only

The type of this event.
Possible values are:

unknown (1)

other (2)

status (3)

configuration (4)

topology (5)

Always set to 2 (other).

connUnitEventObject
1.3.6.1.3.94.1.11.1.8

Read only

This is used with the connUnitEventType to identify to which object the
event refers. It can be the OID of a connectivity unit or of another object,
like connUnitPortStatus.
Always set to null.

connUnitEventDescr
1.3.6.1.3.94.1.11.1.9

Read only

The description of the event.
Same as the string displayed in the system error log. The system error
log can be viewed using the errShow or errDump commands.

For Fabric OS v6.2.0 and later releases, the format of error messages
has changed. This field now uses the message title and number (for
example, WEBD-1006) and the message text. Previously, this field used
the task ID and all the message number and message text. For more
information on error messages, refer to Fabric OS Message Reference.

TABLE 75

Object and OID

Access

Description

Advertising