Connunitsn, Connunituptime, Connuniturl – Dell POWEREDGE M1000E User Manual
Page 228: Connunitdomainid, Connunitproxymaster, Connunitprincipal, Connunitnumsensors, Connunitstatuschangeti me
 
208
Fabric OS MIB Reference
53-1002750-01
Connectivity unit group
9
connUnitSn
1.3.6.1.3.94.1.6.1.8
Read only
The serial number for this connectivity unit.
Set to the SSN (which by default is the WWN).
connUnitUpTime
1.3.6.1.3.94.1.6.1.9
Read only
The number of centiseconds since the last unit initialization.
connUnitUrl
1.3.6.1.3.94.1.6.1.10
Read-write
URL to launch a management application, if applicable; otherwise an 
empty string. In a standalone unit, this would be the same as the 
top-level URL. This has the same definition as systemURL for keywords. 
(Same as systemURL.) The expected value for connUnitURL.0 is:
“http://{a.b.c.d}”
where {a.b.c.d} is the IP address of the switch if Web Tools license is 
available.
 “” (null)
where “” is the IP address of the switch if Web Tools license is not 
available.
connUnitDomainId
1.3.6.1.3.94.1.6.1.11
Read only
24-bit Fibre Channel address ID of this connectivity unit, right-justified 
with leading 0s if required. If this value is not applicable, return all bits to 
one.
Set to the switch domain ID (as per FC-SW).
For a Brocade Access Gateway device, the value is hard coded as “11 11 
11”. A Brocade Access Gateway does not have a domain ID. 
connUnitProxyMaster
1.3.6.1.3.94.1.6.1.12
Read only
A value of “yes” means this is the proxy master unit for a set of managed 
units. 
Possible values are:
•
unknown (1)
•
no (2)
•
yes (3)
This could be the only unit with a management card in it for a set of 
units. A standalone unit should return “yes” for this object.
Set to 3 (yes).
connUnitPrincipal
1.3.6.1.3.94.1.6.1.13
Read only
Indicates whether this connectivity unit is the principal unit within the 
group of fabric elements. If this value is not applicable, it returns 
“unknown”.
If the switch is principal, this is set to 3 (yes); otherwise, for a fabric 
switch it is set to 2 (no). For a Brocade Access Gateway device, since the 
switch is behaving as a device management tool and not a Fibre 
Channel switch, the value is set to 1 (unknown).
Possible values are:
•
unknown (1)
•
no (2)
•
yes (3)
connUnitNumSensors
1.3.6.1.3.94.1.6.1.14
Read only
Number of sensors (between 0 and maximum number of sensors) in the 
connUnitSensorTable. 
For specific sensor counts on the various switches, refer to
connUnitStatusChangeTi
me
1.3.6.1.3.94.1.6.1.15
Read only
The sysuptime time stamp (in centiseconds) at which the last status 
change occurred for any members of the set; this is the latest time 
stamp that connUnitStatus or connUnitPortStatus changed.
NOTE: This object is not supported.
TABLE 75
Object and OID
Access
Description