Connunitsn, Connunituptime, Connuniturl – Dell POWEREDGE M1000E User Manual

Page 228: Connunitdomainid, Connunitproxymaster, Connunitprincipal, Connunitnumsensors, Connunitstatuschangeti me

Advertising
background image

208

Fabric OS MIB Reference

53-1002750-01

Connectivity unit group

9

connUnitSn
1.3.6.1.3.94.1.6.1.8

Read only

The serial number for this connectivity unit.
Set to the SSN (which by default is the WWN).

connUnitUpTime
1.3.6.1.3.94.1.6.1.9

Read only

The number of centiseconds since the last unit initialization.

connUnitUrl
1.3.6.1.3.94.1.6.1.10

Read-write

URL to launch a management application, if applicable; otherwise an
empty string. In a standalone unit, this would be the same as the
top-level URL. This has the same definition as systemURL for keywords.

(Same as systemURL.) The expected value for connUnitURL.0 is:
“http://{a.b.c.d}”
where {a.b.c.d} is the IP address of the switch if Web Tools license is
available.

“” (null)
where “” is the IP address of the switch if Web Tools license is not
available.

connUnitDomainId
1.3.6.1.3.94.1.6.1.11

Read only

24-bit Fibre Channel address ID of this connectivity unit, right-justified
with leading 0s if required. If this value is not applicable, return all bits to
one.
Set to the switch domain ID (as per FC-SW).
For a Brocade Access Gateway device, the value is hard coded as “11 11
11”. A Brocade Access Gateway does not have a domain ID.

connUnitProxyMaster
1.3.6.1.3.94.1.6.1.12

Read only

A value of “yes” means this is the proxy master unit for a set of managed
units.
Possible values are:

unknown (1)

no (2)

yes (3)

This could be the only unit with a management card in it for a set of
units. A standalone unit should return “yes” for this object.
Set to 3 (yes).

connUnitPrincipal
1.3.6.1.3.94.1.6.1.13

Read only

Indicates whether this connectivity unit is the principal unit within the
group of fabric elements. If this value is not applicable, it returns
“unknown”.
If the switch is principal, this is set to 3 (yes); otherwise, for a fabric
switch it is set to 2 (no). For a Brocade Access Gateway device, since the
switch is behaving as a device management tool and not a Fibre
Channel switch, the value is set to 1 (unknown).
Possible values are:

unknown (1)

no (2)

yes (3)

connUnitNumSensors
1.3.6.1.3.94.1.6.1.14

Read only

Number of sensors (between 0 and maximum number of sensors) in the
connUnitSensorTable.
For specific sensor counts on the various switches, refer to

Table 46

on

page 147.

connUnitStatusChangeTi
me
1.3.6.1.3.94.1.6.1.15

Read only

The sysuptime time stamp (in centiseconds) at which the last status
change occurred for any members of the set; this is the latest time
stamp that connUnitStatus or connUnitPortStatus changed.
NOTE: This object is not supported.

TABLE 75

Object and OID

Access

Description