Fcfxconftable, Fcfxconfentry, Fcfxconfmoduleindex – Dell POWEREDGE M1000E User Manual

Page 115: Fcfxconffxportindex, Fcfxportname, Fcfxportfcphversionhigh, Fcfxportfcphversionlow, Fcfxportbbcredit, Fcfxportrxbufsize, Fcfxportratov

Advertising
background image

Fabric OS MIB Reference

95

53-1002750-01

fcFeConfig group

4

fcFxConfTable
1.3.6.1.3.42.2.1.1.5

Not
accessible

A table that contains, one entry for each Fx_Port in the fabric element,
configuration and service parameters of the Fx_Ports.

fcFxConfEntry
1.3.6.1.3.42.2.1.1.5.1

Not
accessible

An entry containing the configuration and service parameters of an
Fx_Port.

fcFxConfModuleIndex
1.3.6.1.3.42.2.1.1.5.1.1

Read only

Identifies the module containing the Fx_Port for which this entry
contains information.

fcFxConfFxPortIndex
1.3.6.1.3.42.2.1.1.5.1.2

Read only

Identifies the Fx_Port within the module. This number ranges from 1
to the value of fcFeModulePortCapacity for the associated module.
The value remains constant for the identified Fx_Port until the module
is re-initialized.

fcFxPortName
1.3.6.1.3.42.2.1.1.5.1.3

Read only

The name identifier of this Fx_Port. Each Fx_Port has a unique port
name within the address space of the fabric.
The return value is the WWN of the port.

fcFxPortFcphVersionHigh
1.3.6.1.3.42.2.1.1.5.1.4

Read only

The highest or most recent version of FC-PH that the Fx_Port is
configured to support.

fcFxPortFcphVersionLow
1.3.6.1.3.42.2.1.1.5.1.5

Read only

The lowest or earliest version of FC-PH that the Fx_Port is configured
to support.

fcFxPortBbCredit
1.3.6.1.3.42.2.1.1.5.1.6

Read only

The total number of receive buffers available for holding Class 1
connect-request Class 2 or 3 frames from the attached Nx_Port. It is
for buffer-to-buffer flow control in the direction from the attached
Nx_Port (if applicable) to Fx_Port.

fcFxPortRxBufSize
1.3.6.1.3.42.2.1.1.5.1.7

Read only

The largest Data_Field Size (in octets) for an FT_1 frame that can be
received by the Fx_Port.

fcFxPortRatov
1.3.6.1.3.42.2.1.1.5.1.8

Read only

The Resource_Allocation_Timeout Value configured for the Fx_Port.
This is used as the time-out value for determining when to reuse an
Nx_Port resource such as a Recovery_Qualifier. It represents E_D_TOV
(Refer to

“fcFxPortEdtov”

on page 80) plus twice the maximum time

that a frame might be delayed within the fabric and still be delivered.

fcFxPortEdtov
1.3.6.1.3.42.2.1.1.5.1.9

Read only

The E_D_TOV value configured for the Fx_Port. The
Error_Detect_Timeout Value is used as the time-out value for
detecting an error condition.

fcFxPortCosSupported
1.3.6.1.3.42.2.1.1.5.1.10

Read only

A value indicating the set of Classes of Service supported by the
Fx_Port.
Valid values:

Class F (0)

Class 1 (1)

Class 2 (2)

Class 3 (3)

Class 4 (4)

Class 5 (5)

Class 6 (6)

fcFxPortIntermixSupported
1.3.6.1.3.42.2.1.1.5.1.11

Read only

A flag indicating whether the Fx_Port supports an Intermixed
Dedicated Connection.
Valid values:

yes (1)

no (2)

TABLE 33

Object and OID

Access

Description