Connunitportname, Connunitportphysicalnu mber, Connunitportstatobject – Dell POWEREDGE M1000E User Manual

Page 239

Advertising
background image

Fabric OS MIB Reference

219

53-1002750-01

Connectivity unit group

9

connUnitPortControl
1.3.6.1.3.94.1.10.1.16
(continued)

Read-write

Return values are:

- resetConnUnitPort portDisable (F or E_Port, loop for U_Port)
- bypassConnUnitPort portDisable (FL_Port)
- unbypassConnUnitPort portEnable (FL_Port)
- offlineConnUnitPort portDisable (E, F, FL_Port)
- onlineConnUnitPort portEnable (U)
- resetConnUnitPortCounters clear the port statistics counter. - -
when rebooted, this defaults to 1 (unknown).

connUnitPortName
1.3.6.1.3.94.1.10.1.17

Read-write

A string describing the addressed port.
NOTE: This object is read only for Brocade switches.

connUnitPortPhysicalNu
mber
1.3.6.1.3.94.1.10.1.18

Read only

This is the internal port number by which this port is known. In many
implementations, this should be the same as connUnitPortIndex. Some
implementations might have an internal port representation not
compatible with the rules for table indices. In these cases, provide the
internal representation of this port in this object. This value might also
be used in the connUnitLinkPortNumberX or connUnitLinkPortNumberY
objects of the connUnitLinkTable.
The internal port numbers for Brocade switch. The Brocade switches
support 0 through maximum number of ports.
The maximum number of supported ports are as follows.

Brocade 300

24 ports

Brocade 4100

32 ports

Brocade 4900

64 ports

Brocade 5000

32 ports

Brocade 5100

40 ports

Brocade 5300

80 ports

Brocade 7500 or 7500E

32 ports

Brocade 7600

16 ports

Brocade 7800 Extension Switch

24 ports

Brocade 8000

32 ports

Brocade Encryption Switch

32 ports

Brocade DCX

640 ports

Brocade DCX-4S

320 ports

Brocade 48000

384 ports

Brocade 6505

24 ports

Brocade 6510

48 ports

Brocade 6520

96 ports

Brocade DCX 8510-4 Backbone

320 ports

Brocade DCX 8510-8 Backbone

640 ports

Brocade VA-40FC

40 ports

connUnitPortStatObject
1.3.6.1.3.94.1.10.1.19

Read only

This OID is deprecated.
This contains the OID of the first object of the table that contains the
statistics for this particular port. If this has a value of 0, then there are
no statistics available for this port. The port type information helps
identify the statistics objects found in the table. From this point, use the
getnext command to get the next statistics object. When the first part of
the OID changes, the end of table is reached.
Mapped to connUnitPortStatFabricUnitId.

TABLE 75

Object and OID

Access

Description

Advertising